<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Instalacje technologiczne Archives - Jerzy Nawrocki</title>
	<atom:link href="https://jureknawrocki.com/en/category/projekty/technologia/feed/" rel="self" type="application/rss+xml" />
	<link>https://jureknawrocki.com/en/category/projekty/technologia/</link>
	<description>dr inż., Rzeczoznawca Izby Inżynierów, SIMP, NOT &#124;&#124; Rurociągi i aparaty ciśnieniowe &#124;&#124; Uprawnienia budowalne HVAC i Gaz &#124;&#124; Spawalnictwo IWE&#38;I &#124;&#124; Certyfikat LE w/g EN 13313-Chłodnictwo i Pompy ciepła</description>
	<lastbuilddate>Sat, 14 Mar 2026 07:11:01 +0000</lastbuilddate>
	<language>en-GB</language>
	<sy:updateperiod>
	hourly	</sy:updateperiod>
	<sy:updatefrequency>
	1	</sy:updatefrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://jureknawrocki.com/wp-content/uploads/Jerzy-Nawrocki-favicon-150x150.webp</url>
	<title>Instalacje technologiczne Archives - Jerzy Nawrocki</title>
	<link>https://jureknawrocki.com/en/category/projekty/technologia/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Co poszło źle cz.I</title>
		<link>https://jureknawrocki.com/en/co-poszlo-zle-cz-i/</link>
					<comments>https://jureknawrocki.com/en/co-poszlo-zle-cz-i/#respond</comments>
		
		<dc:creator><![CDATA[Jerzy Nawrocki]]></dc:creator>
		<pubdate>Thu, 27 Feb 2025 18:51:24 +0000</pubdate>
				<category><![CDATA[Instalacje technologiczne]]></category>
		<category><![CDATA[Obliczenia wytrzymałościowe rur i aparatów]]></category>
		<category><![CDATA[Z życia rzeczoznawcy]]></category>
		<category><![CDATA[HVAC]]></category>
		<guid ispermalink="false">https://jureknawrocki.com/?p=2791</guid>

					<description><![CDATA[<p>Co jakiś czas będę opisywał przypadki z ekspertyz, które robię. Zatem what went wrong pomiędzy Bałtykiem a Tatrami. Poniżej przykład fatalnego zaprojektowania i jeszcze gorszego wykonania bardzo dobrego pomysłu ogrzewania podłogówką tuneli z delikatną produkcją roliczną. Powierzchnia grzejnika podłogowego to &#8230;. 0.22 ha ! W fazie projektu nie policzono zapotrzebowania ciepła na ogrzanie temperatury wewnątrz [&#8230;]</p>
<p>The post <a href="https://jureknawrocki.com/en/co-poszlo-zle-cz-i/">Co poszło źle cz.I</a> appeared first on <a href="https://jureknawrocki.com/en">Jerzy Nawrocki</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>From time to time I will describe cases from expertise that I do. </p>



<p>Below is an example of a terrible design and even worse execution of a very good idea to use floor heating of tunnels where a delicate agricultural production is conducted. The area of ​​the floor  heating is ... 0.22 ha, i.e. 2200 m2 ! Huge.. </p>



<figure class="wp-block-image size-full"><img fetchpriority="high" decoding="async" width="1008" height="767" src="https://jureknawrocki.com/wp-content/uploads/Pompa-ciepla-6.jpg" alt="" class="wp-image-2807" srcset="https://jureknawrocki.com/wp-content/uploads/Pompa-ciepla-6.jpg 1008w, https://jureknawrocki.com/wp-content/uploads/Pompa-ciepla-6-980x746.jpg 980w, https://jureknawrocki.com/wp-content/uploads/Pompa-ciepla-6-480x365.jpg 480w" sizes="(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1008px, 100vw" /></figure>



<figure class="wp-block-image size-full"><img decoding="async" width="1008" height="419" src="https://jureknawrocki.com/wp-content/uploads/Pompa-ciepla-5.jpg" alt="" class="wp-image-2808" srcset="https://jureknawrocki.com/wp-content/uploads/Pompa-ciepla-5.jpg 1008w, https://jureknawrocki.com/wp-content/uploads/Pompa-ciepla-5-980x407.jpg 980w, https://jureknawrocki.com/wp-content/uploads/Pompa-ciepla-5-480x200.jpg 480w" sizes="(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1008px, 100vw" /></figure>



<p>In the design phase, the heat demand for heating the temperature inside all six foil tunnels to 20C was not calculated. This is the first time I have come across a central heating installation project in which the heat demand was not calculated. As a result, the 12 pumps 
 in two cascade generates negligible heat power in relation to the demand. As a result, 60 tons of heating oil are used for one and a half heating seasons (which cost about PLN 350,000) in order to maintain the temperature of +20C inside the tunnels, which is crucial for the investor's delicate agricultural production.</p>



<p>The second very good idea was to build in a heat source from a cascade of air heat pumps. Then we have a perfect combination of a floor heater and a heat pump. This is what people are taught in engineering studies. </p>



<p>Unfortunately, the contractor built two cascades of six (!) heat pumps each. 26,712 hours passed between the day of signing the work completion protocol and the day of reading the controllers. Let's make an optimistic assumption that the heating season in connection with agricultural production in foil tunnels is half a year. This means that the pumps should have worked 13,356 hours. They should have, but they didn't. For example, pump P1 worked 43,859 hours, and the difference between the extreme values ​​of working times was more than 11 times. This is the result of building a cascade of heat or cooling sources in a quantity greater than the optimum, which is usually three. </p>



<p>This is what the floor loop distributor mounted horizontally inside the foil tunnels looks like after two seasons of operation. </p>



<figure class="wp-block-image aligncenter size-large"><img decoding="async" width="1024" height="765" src="https://jureknawrocki.com/wp-content/uploads/Pompa-ciepla-1-1024x765.jpg" alt="" class="wp-image-2794" srcset="https://jureknawrocki.com/wp-content/uploads/Pompa-ciepla-1-1024x765.jpg 1024w, https://jureknawrocki.com/wp-content/uploads/Pompa-ciepla-1-980x732.jpg 980w, https://jureknawrocki.com/wp-content/uploads/Pompa-ciepla-1-480x359.jpg 480w" sizes="(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1024px, 100vw" /></figure>



<p>This is how it should look and how it looks in thousands of normal implementations.  </p>



<figure class="wp-block-image aligncenter size-full is-resized"><img decoding="async" width="706" height="586" src="https://jureknawrocki.com/wp-content/uploads/Pompa-ciepla-4.jpg" alt="" class="wp-image-2800" style="width:431px;height:auto" srcset="https://jureknawrocki.com/wp-content/uploads/Pompa-ciepla-4.jpg 706w, https://jureknawrocki.com/wp-content/uploads/Pompa-ciepla-4-480x398.jpg 480w" sizes="(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 706px, 100vw" /></figure>



<p>An example of mounting a temperature sensor on a valve housing using the proverbial spit.</p>



<figure class="wp-block-image aligncenter size-full"><img decoding="async" width="521" height="505" src="https://jureknawrocki.com/wp-content/uploads/Pompa-ciepla-2.jpg" alt="" class="wp-image-2796" srcset="https://jureknawrocki.com/wp-content/uploads/Pompa-ciepla-2.jpg 521w, https://jureknawrocki.com/wp-content/uploads/Pompa-ciepla-2-480x465.jpg 480w" sizes="(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 521px, 100vw" /></figure>



<p>The installation of all heat pumps was designed on the roof of one container. As a result of this solution, the minimum distances from building partitions were not maintained. The heat pumps are placed face to face. For such a configuration of heat pumps, it is not the minimum service space that is crucial. It is the unobstructed freedom of ventilation air flow for heat exchanger ventilation. A conservative solution should be adopted and the minimum distance should be set at 2C, i.e. 160 cm. The measured distance is 45 cm, so it is ~3.5 times smaller.</p>



<figure class="wp-block-image aligncenter size-full"><img loading="lazy" decoding="async" width="641" height="508" src="https://jureknawrocki.com/wp-content/uploads/Pompa-ciepla-3.jpg" alt="" class="wp-image-2798" srcset="https://jureknawrocki.com/wp-content/uploads/Pompa-ciepla-3.jpg 641w, https://jureknawrocki.com/wp-content/uploads/Pompa-ciepla-3-480x380.jpg 480w" sizes="(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 641px, 100vw" /></figure>



<p>&nbsp;</p><p>The post <a href="https://jureknawrocki.com/en/co-poszlo-zle-cz-i/">Co poszło źle cz.I</a> appeared first on <a href="https://jureknawrocki.com/en">Jerzy Nawrocki</a>.</p>
]]></content:encoded>
					
					<wfw:commentrss>https://jureknawrocki.com/en/co-poszlo-zle-cz-i/feed/</wfw:commentrss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Czystość grafitu a szczelność połączenia kołnierzowego</title>
		<link>https://jureknawrocki.com/en/czystosc-grafitu-a-szczelnosc-polaczenia-kolnierzowego/</link>
					<comments>https://jureknawrocki.com/en/czystosc-grafitu-a-szczelnosc-polaczenia-kolnierzowego/#respond</comments>
		
		<dc:creator><![CDATA[Jerzy Nawrocki]]></dc:creator>
		<pubdate>Thu, 27 Jun 2024 14:17:59 +0000</pubdate>
				<category><![CDATA[Instalacje technologiczne]]></category>
		<category><![CDATA[Z życia rzeczoznawcy]]></category>
		<category><![CDATA[Rurociągi]]></category>
		<guid ispermalink="false">https://jureknawrocki.com/?p=2451</guid>

					<description><![CDATA[<p>Ten post został napisany w oparciu o materiały firmy SPETECH. Jakby ktoś kiedyś miał do czynienia z temperaturami powyżej pełzania, to stosowanie uszczelek z grafitu zanieczyszczonym siarką i fosforem, prowadzi do utlenienia się grafitu w powietrzu, więc na zewnątrz przylgi. Ten proces ubytku masy jest liczony w godzinach, no może w dniach, więc jest na [&#8230;]</p>
<p>The post <a href="https://jureknawrocki.com/en/czystosc-grafitu-a-szczelnosc-polaczenia-kolnierzowego/">Czystość grafitu a szczelność połączenia kołnierzowego</a> appeared first on <a href="https://jureknawrocki.com/en">Jerzy Nawrocki</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>This post was written based on SPETECH materials. If anyone has ever had to deal with temperatures above creep, using graphite gaskets contaminated with sulfur and phosphorus leads to the graphite oxidizing in the air, so outside the seal. This process of mass loss is measured in hours, maybe days, so fortunately it is quick, so it can be noticed.</p>



<figure class="wp-block-image size-full is-resized"><img loading="lazy" decoding="async" width="686" height="445" src="https://jureknawrocki.com/wp-content/uploads/Grafit-1.webp" alt="" class="wp-image-2452" style="width:812px;height:auto" srcset="https://jureknawrocki.com/wp-content/uploads/Grafit-1.webp 686w, https://jureknawrocki.com/wp-content/uploads/Grafit-1-480x311.webp 480w" sizes="(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 686px, 100vw" /></figure>



<p>Here, only the gasket reinforcement remains. The graphite has completely disappeared.</p>



<figure class="wp-block-image size-full is-resized"><img loading="lazy" decoding="async" width="539" height="528" src="https://jureknawrocki.com/wp-content/uploads/Grafit-2.webp" alt="" class="wp-image-2453" style="width:823px;height:auto" srcset="https://jureknawrocki.com/wp-content/uploads/Grafit-2.webp 539w, https://jureknawrocki.com/wp-content/uploads/Grafit-2-480x470.webp 480w" sizes="(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 539px, 100vw" /></figure>



<p>Graphite must be as little contaminated with sulfur and phosphorus as possible. How to test the purity of graphite? This is stated in the standard EN 14772 Flanges and their connections — Quality assurance control and testing of gaskets in accordance with EN 1514 and EN 12560 series standards.</p>



<figure class="wp-block-image size-large"><img loading="lazy" decoding="async" width="1024" height="389" src="https://jureknawrocki.com/wp-content/uploads/Grafit-3-1024x389.webp" alt="" class="wp-image-2454" srcset="https://jureknawrocki.com/wp-content/uploads/Grafit-3-1024x389.webp 1024w, https://jureknawrocki.com/wp-content/uploads/Grafit-3-980x372.webp 980w, https://jureknawrocki.com/wp-content/uploads/Grafit-3-480x182.webp 480w" sizes="(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1024px, 100vw" /></figure><p>The post <a href="https://jureknawrocki.com/en/czystosc-grafitu-a-szczelnosc-polaczenia-kolnierzowego/">Czystość grafitu a szczelność połączenia kołnierzowego</a> appeared first on <a href="https://jureknawrocki.com/en">Jerzy Nawrocki</a>.</p>
]]></content:encoded>
					
					<wfw:commentrss>https://jureknawrocki.com/en/czystosc-grafitu-a-szczelnosc-polaczenia-kolnierzowego/feed/</wfw:commentrss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Punkt rozładunku bardzo łatwopalnej cieczy</title>
		<link>https://jureknawrocki.com/en/punkt-rozladunku-bardzo-latwopalnej-cieczy/</link>
					<comments>https://jureknawrocki.com/en/punkt-rozladunku-bardzo-latwopalnej-cieczy/#respond</comments>
		
		<dc:creator><![CDATA[Jerzy Nawrocki]]></dc:creator>
		<pubdate>Sat, 15 Jun 2024 15:42:24 +0000</pubdate>
				<category><![CDATA[Instalacje technologiczne]]></category>
		<category><![CDATA[Z życia rzeczoznawcy]]></category>
		<category><![CDATA[Rurociągi]]></category>
		<guid ispermalink="false">https://jureknawrocki.com/?p=2407</guid>

					<description><![CDATA[<p>Projektu rozładunku substancji niebezpiecznych przewożonych ciężarówką podlegają uzgodnieniu z inspekcją transportu drogowego. Poniżej przykład realizacji węzła rozładunku octanu etylu &#8211; cieczy skrajnie łatwopalnej. Węże ze złączkami, instrukcja rozładunku, złącze uziemiające i pompownia membranowa.</p>
<p>The post <a href="https://jureknawrocki.com/en/punkt-rozladunku-bardzo-latwopalnej-cieczy/">Punkt rozładunku bardzo łatwopalnej cieczy</a> appeared first on <a href="https://jureknawrocki.com/en">Jerzy Nawrocki</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The project of unloading hazardous substances transported by truck is subject to agreement with the road transport inspection. Below is an example of the implementation of the ethyl acetate unloading node - an extremely flammable liquid. Hoses with connectors, unloading instructions, grounding connector and membrane pumping station.   </p>



<figure class="wp-block-image size-large"><img loading="lazy" decoding="async" width="1024" height="461" src="https://jureknawrocki.com/wp-content/uploads/NO1-1-1024x461.webp" alt="" class="wp-image-2423" srcset="https://jureknawrocki.com/wp-content/uploads/NO1-1-980x441.webp 980w, https://jureknawrocki.com/wp-content/uploads/NO1-1-480x216.webp 480w" sizes="(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1024px, 100vw" /></figure>



<figure class="wp-block-image size-large"><img loading="lazy" decoding="async" width="1024" height="461" src="https://jureknawrocki.com/wp-content/uploads/NO7-1-1024x461.webp" alt="" class="wp-image-2417" srcset="https://jureknawrocki.com/wp-content/uploads/NO7-1-980x441.webp 980w, https://jureknawrocki.com/wp-content/uploads/NO7-1-480x216.webp 480w" sizes="(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1024px, 100vw" /></figure>



<figure class="wp-block-image size-large"><img loading="lazy" decoding="async" width="462" height="1024" src="https://jureknawrocki.com/wp-content/uploads/NO5-1-462x1024.webp" alt="" class="wp-image-2419"/></figure>



<figure class="wp-block-image size-large"><img decoding="async" src="https://jureknawrocki.com/wp-content/uploads/NO8-1024x461.webp" alt="" class="wp-image-2413"/></figure>



<figure class="wp-block-image size-large"><img loading="lazy" decoding="async" width="462" height="1024" src="https://jureknawrocki.com/wp-content/uploads/NO3-1-462x1024.webp" alt="" class="wp-image-2421"/></figure>



<figure class="wp-block-image size-large"><img loading="lazy" decoding="async" width="462" height="1024" src="https://jureknawrocki.com/wp-content/uploads/NO4-1-462x1024.webp" alt="" class="wp-image-2420"/></figure><p>The post <a href="https://jureknawrocki.com/en/punkt-rozladunku-bardzo-latwopalnej-cieczy/">Punkt rozładunku bardzo łatwopalnej cieczy</a> appeared first on <a href="https://jureknawrocki.com/en">Jerzy Nawrocki</a>.</p>
]]></content:encoded>
					
					<wfw:commentrss>https://jureknawrocki.com/en/punkt-rozladunku-bardzo-latwopalnej-cieczy/feed/</wfw:commentrss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Izolacja aparatu dla TS=430C</title>
		<link>https://jureknawrocki.com/en/izolacja-aparatu-dla-ts430c/</link>
					<comments>https://jureknawrocki.com/en/izolacja-aparatu-dla-ts430c/#respond</comments>
		
		<dc:creator><![CDATA[Jerzy Nawrocki]]></dc:creator>
		<pubdate>Sun, 02 Jun 2024 06:09:06 +0000</pubdate>
				<category><![CDATA[Instalacje technologiczne]]></category>
		<category><![CDATA[Z życia rzeczoznawcy]]></category>
		<category><![CDATA[MES]]></category>
		<guid ispermalink="false">https://jureknawrocki.com/?p=2392</guid>

					<description><![CDATA[<p>The post <a href="https://jureknawrocki.com/en/izolacja-aparatu-dla-ts430c/">Izolacja aparatu dla TS=430C</a> appeared first on <a href="https://jureknawrocki.com/en">Jerzy Nawrocki</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="et_pb_section et_pb_section_0 et_section_regular" >
				
				
				
				
				
				
				<div class="et_pb_row et_pb_row_0">
				<div class="et_pb_column et_pb_column_4_4 et_pb_column_0  et_pb_css_mix_blend_mode_passthrough et-last-child">
				
				
				
				
				<div class="et_pb_module et_pb_text et_pb_text_0  et_pb_text_align_left et_pb_bg_layout_light">
				
				
				
				
				<div class="et_pb_text_inner"><!-- divi:paragraph -->
<p>Poniżej przykład projektu izolacji aparatu pracującego powyżej temperatury pełzania. Grubość ścianki to&nbsp;100 mm. </p>
<!-- /divi:paragraph -->

<!-- divi:image {"id":2393,"sizeSlug":"large","linkDestination":"none"} -->
<figure class="wp-block-image size-large"><img loading="lazy" decoding="async" width="1024" height="724" src="https://jureknawrocki.com/wp-content/uploads/Izolacja-430-C-5-1024x724.webp" alt="" class="wp-image-2393" srcset="https://jureknawrocki.com/wp-content/uploads/Izolacja-430-C-5-1024x724.webp 1024w, https://jureknawrocki.com/wp-content/uploads/Izolacja-430-C-5-980x693.webp 980w, https://jureknawrocki.com/wp-content/uploads/Izolacja-430-C-5-480x339.webp 480w" sizes="(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1024px, 100vw" /></figure>
<!-- /divi:image -->

<!-- divi:paragraph -->
<p>According to the mechanical design, the temperature of the external surface of the device was assumed to be +4290C. The maximum possible insulation thickness was assumed to be 150 mm. The use of thicker insulation is not possible due to the specific design of the device and the shape of the connection stubs.<br>Wyznaczenie kluczowej danej, to&nbsp;jest  współczynnika przejmowania ciepła z&nbsp;powierzchni poziomego aparatu przy konwekcji swobodnej w&nbsp;przestrzeni nieograniczonej wyznaczono według ogólnie znanych reguł teorii podobieństwa. </p>
<!-- /divi:paragraph -->

<!-- divi:paragraph -->
<p>Due to the significant dependence of the thermal conductivity coefficient of mineral wool on temperature, the finite element method was used. The quality level of the mesh used on the external surface is close to unity, so the mesh error is negligible.  </p>
<!-- /divi:paragraph -->

<!-- divi:image {"id":2394,"sizeSlug":"full","linkDestination":"none"} -->
<figure class="wp-block-image size-full"><img loading="lazy" decoding="async" width="956" height="351" src="https://jureknawrocki.com/wp-content/uploads/Izolacja-430-C-3.webp" alt="" class="wp-image-2394" srcset="https://jureknawrocki.com/wp-content/uploads/Izolacja-430-C-3.webp 956w, https://jureknawrocki.com/wp-content/uploads/Izolacja-430-C-3-480x176.webp 480w" sizes="(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 956px, 100vw" /></figure>
<!-- /divi:image -->

<!-- divi:paragraph -->
<p>Poniżej przedstawiono wyniki. </p>
<!-- /divi:paragraph -->

<!-- divi:image {"id":2371,"width":"677px","height":"auto","sizeSlug":"full","linkDestination":"none","align":"center"} -->
<figure class="wp-block-image aligncenter size-full is-resized"><img loading="lazy" decoding="async" width="555" height="446" src="https://jureknawrocki.com/wp-content/uploads/Izolacja-430-C-1.webp" alt="" class="wp-image-2371" style="width:677px;height:auto" srcset="https://jureknawrocki.com/wp-content/uploads/Izolacja-430-C-1.webp 555w, https://jureknawrocki.com/wp-content/uploads/Izolacja-430-C-1-480x386.webp 480w" sizes="(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 555px, 100vw" /></figure>
<!-- /divi:image -->

<!-- divi:image {"id":2395,"sizeSlug":"full","linkDestination":"none","align":"center"} -->
<figure class="wp-block-image aligncenter size-full"><img loading="lazy" decoding="async" width="564" height="454" src="https://jureknawrocki.com/wp-content/uploads/Izolacja-430-C-2.webp" alt="" class="wp-image-2395" srcset="https://jureknawrocki.com/wp-content/uploads/Izolacja-430-C-2.webp 564w, https://jureknawrocki.com/wp-content/uploads/Izolacja-430-C-2-480x386.webp 480w" sizes="(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 564px, 100vw" /></figure>
<!-- /divi:image --></div>
			</div>
			</div>
				
				
				
				
			</div>
				
				
			</div><p>The post <a href="https://jureknawrocki.com/en/izolacja-aparatu-dla-ts430c/">Izolacja aparatu dla TS=430C</a> appeared first on <a href="https://jureknawrocki.com/en">Jerzy Nawrocki</a>.</p>
]]></content:encoded>
					
					<wfw:commentrss>https://jureknawrocki.com/en/izolacja-aparatu-dla-ts430c/feed/</wfw:commentrss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Nuklearna próżnia</title>
		<link>https://jureknawrocki.com/en/nuklearna-proznia/</link>
		
		<dc:creator><![CDATA[Jerzy Nawrocki]]></dc:creator>
		<pubdate>Wed, 07 Feb 2024 15:17:44 +0000</pubdate>
				<category><![CDATA[Instalacje technologiczne]]></category>
		<category><![CDATA[Obliczenia wytrzymałościowe rur i aparatów]]></category>
		<category><![CDATA[Z życia rzeczoznawcy]]></category>
		<category><![CDATA[Nuke]]></category>
		<guid ispermalink="false">http://www.jureknawrocki.com/?p=1213</guid>

					<description><![CDATA[<p>Poniżej kilka fotek z kalkulacji nuklearnej próżni. Nacisk na dokładność modelu jest duży. Jak można sprawdzić czy model jest dobry ? Wygenerować izometryk.</p>
<p>The post <a href="https://jureknawrocki.com/en/nuklearna-proznia/">Nuklearna próżnia</a> appeared first on <a href="https://jureknawrocki.com/en">Jerzy Nawrocki</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Poniżej kilka fotek z kalkulacji nuklearnej próżni. Nacisk na dokładność modelu jest duży. Jak można sprawdzić czy model jest dobry ? Wygenerować izometryk.</p>
<p><img loading="lazy" decoding="async" class="alignnone  wp-image-1434" src="https://jn.proklik.pl/wp-content/uploads/proznia-1-300x264.webp" alt="" width="297" height="261" srcset="https://jureknawrocki.com/wp-content/uploads/proznia-1-300x264.webp 300w, https://jureknawrocki.com/wp-content/uploads/proznia-1.webp 411w" sizes="(max-width: 297px) 100vw, 297px" /><img loading="lazy" decoding="async" class="alignnone  wp-image-1436" src="https://jn.proklik.pl/wp-content/uploads/Proznia-2-300x248.webp" alt="" width="320" height="264" /></p>
<p><img loading="lazy" decoding="async" class="alignnone size-medium wp-image-1437" src="https://jn.proklik.pl/wp-content/uploads/Proznia-3-212x300.webp" alt="" width="212" height="300" /></p><p>The post <a href="https://jureknawrocki.com/en/nuklearna-proznia/">Nuklearna próżnia</a> appeared first on <a href="https://jureknawrocki.com/en">Jerzy Nawrocki</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Tak brzmi uderzenie hydrauliczne kondensatu pary</title>
		<link>https://jureknawrocki.com/en/jak-brzmi-uderzenie-hydrauliczne-kondensatu-pary/</link>
		
		<dc:creator><![CDATA[Jerzy Nawrocki]]></dc:creator>
		<pubdate>Fri, 22 Sep 2023 09:06:28 +0000</pubdate>
				<category><![CDATA[Instalacje budowalne]]></category>
		<category><![CDATA[Instalacje technologiczne]]></category>
		<category><![CDATA[Obliczenia wytrzymałościowe rur i aparatów]]></category>
		<category><![CDATA[Z życia rzeczoznawcy]]></category>
		<guid ispermalink="false">http://www.jureknawrocki.com/?p=1099</guid>

					<description><![CDATA[<p>Powodem uderzenie hydrauliczne, które słychać poniżej jest niewielka ilość kondensatu pary wodnej. Naprawdę niewielka bo w wypadku dużej ilości rura aż podskakuje na podporach. Odwodnienie kondensatu pary wodnej jest realizowane w tzw garnkach kondensacyjnych. Nie ma na to norm ale może tak to wyglądać: &#160;</p>
<p>The post <a href="https://jureknawrocki.com/en/jak-brzmi-uderzenie-hydrauliczne-kondensatu-pary/">Tak brzmi uderzenie hydrauliczne kondensatu pary</a> appeared first on <a href="https://jureknawrocki.com/en">Jerzy Nawrocki</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Powodem uderzenie hydrauliczne, które słychać poniżej jest <strong>niewielka</strong> ilość kondensatu pary wodnej. Naprawdę niewielka bo w wypadku dużej ilości rura aż podskakuje na podporach.</p>
<p><div style="width: 208px;" class="wp-video"><video class="wp-video-shortcode" id="video-1099-1" width="208" height="292" preload="metadata" controls="controls"><source type="video/webm" src="/wp-content/uploads/2023/09/Uderzenie-kondensatu.webm?_=1" /><a href="/wp-content/uploads/2023/09/Uderzenie-kondensatu.webm">/wp-content/uploads/2023/09/Uderzenie-kondensatu.webm</a></video></div></p>
<p>Odwodnienie kondensatu pary wodnej jest realizowane w tzw garnkach kondensacyjnych. Nie ma na to norm ale może tak to wyglądać:</p>
<p><a href="/wp-content/uploads/2023/09/Uderzenie-kondensatu.png"><img loading="lazy" decoding="async" class="alignnone size-full wp-image-1102" src="/wp-content/uploads/2023/09/Uderzenie-kondensatu.png" alt="" width="481" height="588" /></a></p>
<p>&nbsp;</p><p>The post <a href="https://jureknawrocki.com/en/jak-brzmi-uderzenie-hydrauliczne-kondensatu-pary/">Tak brzmi uderzenie hydrauliczne kondensatu pary</a> appeared first on <a href="https://jureknawrocki.com/en">Jerzy Nawrocki</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Jak nie robić rozdzielacza</title>
		<link>https://jureknawrocki.com/en/jak-nie-robic-rozdzielacza/</link>
		
		<dc:creator><![CDATA[Jerzy Nawrocki]]></dc:creator>
		<pubdate>Tue, 01 Aug 2023 11:58:32 +0000</pubdate>
				<category><![CDATA[Instalacje technologiczne]]></category>
		<category><![CDATA[Obliczenia wytrzymałościowe rur i aparatów]]></category>
		<category><![CDATA[Z życia rzeczoznawcy]]></category>
		<category><![CDATA[Naprężenia]]></category>
		<guid ispermalink="false">http://www.jureknawrocki.com/?p=1022</guid>

					<description><![CDATA[<p>Nie można nigdy robić serii zwężek. Wynika to z faktu, że na kołnierzu są potem przekroczenia ponad 250%</p>
<p>The post <a href="https://jureknawrocki.com/en/jak-nie-robic-rozdzielacza/">Jak nie robić rozdzielacza</a> appeared first on <a href="https://jureknawrocki.com/en">Jerzy Nawrocki</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Nie można nigdy robić serii zwężek. Wynika to z faktu, że na kołnierzu są potem przekroczenia ponad 250%</p>
<p style="text-align: center;"><img loading="lazy" decoding="async" class="alignnone size-full wp-image-1598" src="https://jn.proklik.pl/wp-content/uploads/Rozdzielacz-2.webp" alt="" width="457" height="378" srcset="https://jureknawrocki.com/wp-content/uploads/Rozdzielacz-2.webp 457w, https://jureknawrocki.com/wp-content/uploads/Rozdzielacz-2-300x248.webp 300w" sizes="(max-width: 457px) 100vw, 457px" /></p>
<p style="text-align: center;"><img loading="lazy" decoding="async" class="alignnone size-full wp-image-1597" src="https://jn.proklik.pl/wp-content/uploads/Rozdzielacz-1.webp" alt="" width="2546" height="1542" srcset="https://jn.proklik.pl/wp-content/uploads/Rozdzielacz-1.webp 2546w, https://jn.proklik.pl/wp-content/uploads/Rozdzielacz-1-1280x775.webp 1280w, https://jn.proklik.pl/wp-content/uploads/Rozdzielacz-1-980x594.webp 980w, https://jn.proklik.pl/wp-content/uploads/Rozdzielacz-1-480x291.webp 480w" sizes="(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) and (max-width: 1280px) 1280px, (min-width: 1281px) 2546px, 100vw" /></p><p>The post <a href="https://jureknawrocki.com/en/jak-nie-robic-rozdzielacza/">Jak nie robić rozdzielacza</a> appeared first on <a href="https://jureknawrocki.com/en">Jerzy Nawrocki</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Wpałki &#8211; jak sobie poradzić</title>
		<link>https://jureknawrocki.com/en/wpalki-jak-sobie-poradzic/</link>
		
		<dc:creator><![CDATA[Jerzy Nawrocki]]></dc:creator>
		<pubdate>Mon, 17 Jul 2023 15:02:59 +0000</pubdate>
				<category><![CDATA[Instalacje technologiczne]]></category>
		<category><![CDATA[Obliczenia wytrzymałościowe rur i aparatów]]></category>
		<category><![CDATA[Z życia rzeczoznawcy]]></category>
		<category><![CDATA[Naprężenia]]></category>
		<guid ispermalink="false">http://www.jureknawrocki.com/?p=992</guid>

					<description><![CDATA[<p>Systemy niskoparametrowe mają tzw &#8222;wpałki&#8221;. Ostatnio nawet widziałem je na 15 barowej parze wodnej. Do projektanta nalezy ocena czy  jechać z weldoletem czy też można pozwolić spawaczom iśc na skróty i przystać na wpałkę. Osobiście ich nie lubię, no może z wyjątkiem wody chłodniczej i prostych instalacji grzewczych. Podaję przepis z B31.3. Jerzy Nawrocki &#8211; Wpałka B31.3</p>
<p>The post <a href="https://jureknawrocki.com/en/wpalki-jak-sobie-poradzic/">Wpałki &#8211; jak sobie poradzić</a> appeared first on <a href="https://jureknawrocki.com/en">Jerzy Nawrocki</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Systemy niskoparametrowe mają tzw &#8222;wpałki&#8221;. Ostatnio nawet widziałem je na 15 barowej parze wodnej. Do projektanta nalezy ocena czy  jechać z weldoletem czy też można pozwolić spawaczom iśc na skróty i przystać na wpałkę. Osobiście ich nie lubię, no może z wyjątkiem wody chłodniczej i prostych instalacji grzewczych.</p>
<p>Podaję przepis z B31.3. <a href="https://jn.proklik.pl/wp-content/uploads/Wpalka-B31.3.pdf">Jerzy Nawrocki &#8211; Wpałka B31.3</a></p>
<p><a href="/wp-content/uploads/2023/07/wpalka.jpg"><img loading="lazy" decoding="async" class="alignnone wp-image-995" src="/wp-content/uploads/2023/07/wpalka.jpg" alt="" width="493" height="411" /></a></p><p>The post <a href="https://jureknawrocki.com/en/wpalki-jak-sobie-poradzic/">Wpałki &#8211; jak sobie poradzić</a> appeared first on <a href="https://jureknawrocki.com/en">Jerzy Nawrocki</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Izolacja aparatów i rurociągów czyli liczby podobieństwa</title>
		<link>https://jureknawrocki.com/en/izolacja-aparatow-i-rurociagow-czyli-liczby-podobienstwa/</link>
		
		<dc:creator><![CDATA[Jerzy Nawrocki]]></dc:creator>
		<pubdate>Fri, 14 Jul 2023 20:03:30 +0000</pubdate>
				<category><![CDATA[Instalacje technologiczne]]></category>
		<category><![CDATA[Z życia rzeczoznawcy]]></category>
		<category><![CDATA[Izolacja]]></category>
		<guid ispermalink="false">http://www.jureknawrocki.com/?p=985</guid>

					<description><![CDATA[<p>Wbrew pozorom izolacja to nie jest to bułka z masłem, gdy wewnątrz aparat jest 320 C. Nie ma nic bardziej praktycznego niż porządna teoria wiec warto czasem wrócić do liczb podobieństwa Reynoldsa, Nusselta i Grashofa. Z uwagi na znaczą zależność współczynnika przewodzenia ciepła l od temperatury pracy zastosować trzeba metodę elementów skończonych. Nie da się [&#8230;]</p>
<p>The post <a href="https://jureknawrocki.com/en/izolacja-aparatow-i-rurociagow-czyli-liczby-podobienstwa/">Izolacja aparatów i rurociągów czyli liczby podobieństwa</a> appeared first on <a href="https://jureknawrocki.com/en">Jerzy Nawrocki</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Wbrew pozorom izolacja to nie jest to bułka z masłem, gdy wewnątrz aparat jest 320 C. Nie ma nic bardziej praktycznego niż porządna teoria wiec warto czasem wrócić do liczb podobieństwa Reynoldsa, Nusselta i Grashofa.</p>
<p style="text-align: center;"><img loading="lazy" decoding="async" class="alignnone size-full wp-image-1607" src="https://jn.proklik.pl/wp-content/uploads/Izolacja-1.webp" alt="" width="454" height="598" srcset="https://jureknawrocki.com/wp-content/uploads/Izolacja-1.webp 454w, https://jureknawrocki.com/wp-content/uploads/Izolacja-1-228x300.webp 228w" sizes="(max-width: 454px) 100vw, 454px" /></p>
<p>Z uwagi na znaczą zależność współczynnika przewodzenia ciepła l od temperatury pracy zastosować trzeba metodę elementów skończonych. Nie da się tego policzyć na kartce.</p>
<p>Przyjęto warunek brzegowy temperatury zewnętrznej powierzchni izolacji równy +70<sup>0</sup>C. Jako wytyczną przyjęto zapis w normie Norsok R – 004, w której w punkcie 3.3 przyjmuje się, że graniczna temperatura zewnętrznej powierzchni izolacji wynosi od -10<sup>0</sup>C do +70<sup>0</sup>C. Obecnie nie istnieją obowiązujące w Polsce w tej dziedzinie przepisy.</p>
<p>Wyznaczenie współczynnika przejmowania ciepła z powierzchni poziomego i pionowego rurociągu przy konwekcji swobodnej w przestrzeni nieograniczonej przedstawiono poniżej.</p>
<p style="text-align: center;"><img loading="lazy" decoding="async" class="alignnone size-full wp-image-1609" src="https://jn.proklik.pl/wp-content/uploads/Izolacja-2.webp" alt="" width="600" height="497" srcset="https://jn.proklik.pl/wp-content/uploads/Izolacja-2.webp 600w, https://jn.proklik.pl/wp-content/uploads/Izolacja-2-480x398.webp 480w" sizes="(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 600px, 100vw" /></p>
<p>Wymiana ciepła przez promieniowanie też wzięto pod uwagę. Wynikiem jest analiza przedstawiona poniżej.</p>
<p style="text-align: center;"><img loading="lazy" decoding="async" class="alignnone size-full wp-image-1611" src="https://jn.proklik.pl/wp-content/uploads/Izolacja-3.webp" alt="" width="389" height="485" srcset="https://jureknawrocki.com/wp-content/uploads/Izolacja-3.webp 389w, https://jureknawrocki.com/wp-content/uploads/Izolacja-3-241x300.webp 241w" sizes="(max-width: 389px) 100vw, 389px" /></p>
<p style="text-align: center;"><img loading="lazy" decoding="async" class="alignnone size-full wp-image-1610" src="https://jn.proklik.pl/wp-content/uploads/Izolacja-4.webp" alt="" width="399" height="518" srcset="https://jureknawrocki.com/wp-content/uploads/Izolacja-4.webp 399w, https://jureknawrocki.com/wp-content/uploads/Izolacja-4-231x300.webp 231w" sizes="(max-width: 399px) 100vw, 399px" /></p>
<p style="text-align: center;"><p>The post <a href="https://jureknawrocki.com/en/izolacja-aparatow-i-rurociagow-czyli-liczby-podobienstwa/">Izolacja aparatów i rurociągów czyli liczby podobieństwa</a> appeared first on <a href="https://jureknawrocki.com/en">Jerzy Nawrocki</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Manometr na 10 tyś bar</title>
		<link>https://jureknawrocki.com/en/manometr-na-10-tys-bar/</link>
		
		<dc:creator><![CDATA[Jerzy Nawrocki]]></dc:creator>
		<pubdate>Fri, 07 Jul 2023 09:31:05 +0000</pubdate>
				<category><![CDATA[Instalacje technologiczne]]></category>
		<category><![CDATA[Z życia rzeczoznawcy]]></category>
		<category><![CDATA[Naprężenia]]></category>
		<guid ispermalink="false">http://www.jureknawrocki.com/?p=974</guid>

					<description><![CDATA[<p>U mnie w wiejskim sklepie hydraulicznym jest manometr na 10 razy głębokość Rowu Mariańskiego. Wyprodukowano go w 1966 roku w Sowietach. Ciekawe jaki proces wymagał pomiaru takiego ciśnienia ? Króciec ma wlot jak łepek od szpilki i tył i tył</p>
<p>The post <a href="https://jureknawrocki.com/en/manometr-na-10-tys-bar/">Manometr na 10 tyś bar</a> appeared first on <a href="https://jureknawrocki.com/en">Jerzy Nawrocki</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>U mnie w wiejskim sklepie hydraulicznym jest manometr na 10 razy głębokość Rowu Mariańskiego. Wyprodukowano go w 1966 roku w Sowietach. Ciekawe jaki proces wymagał pomiaru takiego ciśnienia ?</p>
<p style="text-align: center;"><img loading="lazy" decoding="async" class="alignnone size-full wp-image-1615" src="https://jn.proklik.pl/wp-content/uploads/Manometr-10-tys-bar-1-scaled.webp" alt="" width="2560" height="1920" srcset="https://jn.proklik.pl/wp-content/uploads/Manometr-10-tys-bar-1-scaled.webp 2560w, https://jn.proklik.pl/wp-content/uploads/Manometr-10-tys-bar-1-1280x960.webp 1280w, https://jn.proklik.pl/wp-content/uploads/Manometr-10-tys-bar-1-980x735.webp 980w, https://jn.proklik.pl/wp-content/uploads/Manometr-10-tys-bar-1-480x360.webp 480w" sizes="(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) and (max-width: 1280px) 1280px, (min-width: 1281px) 2560px, 100vw" /></p>
<p>Króciec ma wlot jak łepek od szpilki</p>
<p style="text-align: center;"><img loading="lazy" decoding="async" class="alignnone size-full wp-image-1616" src="https://jn.proklik.pl/wp-content/uploads/Manometr-10-tys-bar-2-scaled.webp" alt="" width="1920" height="2560" srcset="https://jn.proklik.pl/wp-content/uploads/Manometr-10-tys-bar-2-scaled.webp 1920w, https://jn.proklik.pl/wp-content/uploads/Manometr-10-tys-bar-2-1280x1707.webp 1280w, https://jn.proklik.pl/wp-content/uploads/Manometr-10-tys-bar-2-980x1307.webp 980w, https://jn.proklik.pl/wp-content/uploads/Manometr-10-tys-bar-2-480x640.webp 480w" sizes="(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) and (max-width: 1280px) 1280px, (min-width: 1281px) 1920px, 100vw" /></p>
<p>i tył</p>
<p style="text-align: center;"><img loading="lazy" decoding="async" class="alignnone size-full wp-image-1617" src="https://jn.proklik.pl/wp-content/uploads/Manometr-10-tys-bar-3-scaled.webp" alt="" width="1920" height="2560" srcset="https://jn.proklik.pl/wp-content/uploads/Manometr-10-tys-bar-3-scaled.webp 1920w, https://jn.proklik.pl/wp-content/uploads/Manometr-10-tys-bar-3-1280x1707.webp 1280w, https://jn.proklik.pl/wp-content/uploads/Manometr-10-tys-bar-3-980x1307.webp 980w, https://jn.proklik.pl/wp-content/uploads/Manometr-10-tys-bar-3-480x640.webp 480w" sizes="(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) and (max-width: 1280px) 1280px, (min-width: 1281px) 1920px, 100vw" /></p>
<p>i tył</p><p>The post <a href="https://jureknawrocki.com/en/manometr-na-10-tys-bar/">Manometr na 10 tyś bar</a> appeared first on <a href="https://jureknawrocki.com/en">Jerzy Nawrocki</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>