<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>PVC Archives - Jerzy Nawrocki</title>
	<atom:link href="https://jureknawrocki.com/tag/pvc/feed/" rel="self" type="application/rss+xml" />
	<link>https://jureknawrocki.com/tag/pvc/</link>
	<description>dr inż., Rzeczoznawca Izby Inżynierów, SIMP, NOT &#124;&#124; Rurociągi i aparaty ciśnieniowe &#124;&#124; Uprawnienia budowalne HVAC i Gaz &#124;&#124; Spawalnictwo IWE&#38;I &#124;&#124; Certyfikat LE w/g EN 13313-Chłodnictwo i Pompy ciepła</description>
	<lastBuildDate>Sat, 14 Mar 2026 07:11:33 +0000</lastBuildDate>
	<language>pl-PL</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://jureknawrocki.com/wp-content/uploads/Jerzy-Nawrocki-favicon-150x150.webp</url>
	<title>PVC Archives - Jerzy Nawrocki</title>
	<link>https://jureknawrocki.com/tag/pvc/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Co mogło pójść źle cz.II</title>
		<link>https://jureknawrocki.com/co-moglo-pojsc-zle-cz-ii/</link>
					<comments>https://jureknawrocki.com/co-moglo-pojsc-zle-cz-ii/#respond</comments>
		
		<dc:creator><![CDATA[Jerzy Nawrocki]]></dc:creator>
		<pubDate>Thu, 31 Jul 2025 15:57:21 +0000</pubDate>
				<category><![CDATA[Ekspertyzy]]></category>
		<category><![CDATA[Instalacje budowalne]]></category>
		<category><![CDATA[Obliczenia wytrzymałościowe rur i aparatów]]></category>
		<category><![CDATA[Z życia rzeczoznawcy]]></category>
		<category><![CDATA[Naprężenia]]></category>
		<category><![CDATA[PVC]]></category>
		<category><![CDATA[Rurociągi]]></category>
		<guid isPermaLink="false">https://jureknawrocki.com/?p=3007</guid>

					<description><![CDATA[<p>Niedawno zrobiłem ekspertyzę, która przedstawiła uzasadnioną odpowiedź na prawdopodobną przyczynę awarii rurociągów instalacji wody chłodniczej PVC DN 280. W ten spoób oddalone zostały roszczenia na około 100 tyś Euro. Awaria polegała na rozszczelnieniu się połączeń klejowych podczas próby ciśnienia. Instalacja w rzucie mieściła się w prostokącie 130 x 30 m. Wykonawca instalacji w celu uwiarygodnienie [&#8230;]</p>
<p>The post <a href="https://jureknawrocki.com/co-moglo-pojsc-zle-cz-ii/">Co mogło pójść źle cz.II</a> appeared first on <a href="https://jureknawrocki.com">Jerzy Nawrocki</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<p class="has-text-align-left">Niedawno zrobiłem ekspertyzę, która przedstawiła uzasadnioną odpowiedź na prawdopodobną przyczynę awarii rurociągów instalacji wody chłodniczej PVC DN 280. W ten spoób oddalone zostały roszczenia na około 100 tyś Euro. Awaria polegała na rozszczelnieniu się połączeń klejowych podczas próby ciśnienia. Instalacja w rzucie mieściła się w prostokącie 130 x 30 m. Wykonawca instalacji w celu uwiarygodnienie swojego roszczenia w stosunku do producenta rur zlecił wykonanie ekspertyzy, która strwedza, że powodem przecieu jest nadmierna owalizacja rur. Jest to całkowicie błędne stanowisko, ponieważ w tablicy 1 pod tytułem „Nominalne średnice zewnętrzne i ich tolerancje” zawartej w normie PN – EN ISO 1452 – 2:2010 rur o klasie ciśnienia PN10 S10 (SDR21) dotyczy komentarz d :..&#8221;Wymagania dotyczące owalności stosuje się tylko do rur przed opuszczeniem siedziby producenta.&#8221;</p>



<p class="has-text-align-left">W związku z powyższym producen podejrzewał, że prawdziwą przyczyną awarii są błedy podczas klejenia połączeń.  Mufy przeciętu na pół i wyznaczonych miejscach oceniono jakość klejenia.</p>



<figure class="wp-block-image aligncenter size-full is-resized"><img fetchpriority="high" decoding="async" width="800" height="528" src="https://jureknawrocki.com/wp-content/uploads/1-2.jpg" alt="" class="wp-image-3008" style="width:462px;height:auto" srcset="https://jureknawrocki.com/wp-content/uploads/1-2.jpg 800w, https://jureknawrocki.com/wp-content/uploads/1-2-480x317.jpg 480w" sizes="(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 800px, 100vw" /></figure>



<p>Na poniższym zdjęciu widoczny jest brak ukosowania krawędzi prawej rury co jest niezgodne z wymaganiami producenta rur opisanymi w instrukcji klejenia.</p>



<figure class="wp-block-image aligncenter size-large is-resized"><img decoding="async" width="1024" height="768" src="https://jureknawrocki.com/wp-content/uploads/2-2-1024x768.jpg" alt="" class="wp-image-3009" style="width:625px;height:auto" srcset="https://jureknawrocki.com/wp-content/uploads/2-2-980x735.jpg 980w, https://jureknawrocki.com/wp-content/uploads/2-2-480x360.jpg 480w" sizes="(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1024px, 100vw" /></figure>



<p>Na poniższym zdjęciu widoczny jest brak warstwy kleju jest na całej głębokości wsunięcia rury w mufę, co w zasadzie jest źródłem nieszczelności. Ukosowanie końca rury było wykonane, ale nie położono wystarczającej warstwy kleju.</p>



<figure class="wp-block-image size-large"><img decoding="async" width="1024" height="768" src="https://jureknawrocki.com/wp-content/uploads/4-2-1024x768.jpg" alt="" class="wp-image-3011" srcset="https://jureknawrocki.com/wp-content/uploads/4-2-980x735.jpg 980w, https://jureknawrocki.com/wp-content/uploads/4-2-480x360.jpg 480w" sizes="(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1024px, 100vw" /></figure>



<p>Na poniższym zdjęciu widoczny jest brak warstwy kleju jest na około ¾ głębokości wsunięcia rury w mufę. Ukosowanie końca rury było wykonane, ale nie położono wystarczającej warstwy kleju.</p>



<figure class="wp-block-image size-large"><img decoding="async" width="1024" height="768" src="https://jureknawrocki.com/wp-content/uploads/5-2-1024x768.jpg" alt="" class="wp-image-3012" srcset="https://jureknawrocki.com/wp-content/uploads/5-2-980x735.jpg 980w, https://jureknawrocki.com/wp-content/uploads/5-2-480x360.jpg 480w" sizes="(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1024px, 100vw" /></figure>



<p>Na poniższych zdjęciach przedstawiono fragmenty złącza pokazujące brak kleju na głębokości kilku milimetrów. Wyraźnie widoczna jest błyszcząca, bez zarysowania, powierzchnia rury, co jest dowodem na brak ingerencji autora w złącze klejone podczas wykonywania badań.&nbsp;</p>



<figure class="wp-block-image aligncenter size-full is-resized"><img decoding="async" width="507" height="363" src="https://jureknawrocki.com/wp-content/uploads/6-2.jpg" alt="" class="wp-image-3013" style="width:511px;height:auto" srcset="https://jureknawrocki.com/wp-content/uploads/6-2.jpg 507w, https://jureknawrocki.com/wp-content/uploads/6-2-480x344.jpg 480w" sizes="(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 507px, 100vw" /></figure>



<p>W celu pokazania jak wygląda obraz mikroskopowy prawidłowo wykonanego złącza wykonano badanie innej kształtki. Widać wyraźnie cienką linię ciemniejszą od sąsiednich fragmentów. Jest to właśnie warstwa kleju nałożona w prawidłowy sposób.</p>



<figure class="wp-block-image size-full is-resized"><img loading="lazy" decoding="async" width="360" height="254" src="https://jureknawrocki.com/wp-content/uploads/7-2.jpg" alt="" class="wp-image-3014" style="width:823px;height:auto" srcset="https://jureknawrocki.com/wp-content/uploads/7-2.jpg 360w, https://jureknawrocki.com/wp-content/uploads/7-2-300x212.jpg 300w, https://jureknawrocki.com/wp-content/uploads/7-2-18x12.jpg 18w" sizes="(max-width: 360px) 100vw, 360px" /></figure>



<p>&nbsp;&nbsp;&nbsp;</p>



<p><br><br></p>



<p><br></p>
<p>The post <a href="https://jureknawrocki.com/co-moglo-pojsc-zle-cz-ii/">Co mogło pójść źle cz.II</a> appeared first on <a href="https://jureknawrocki.com">Jerzy Nawrocki</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://jureknawrocki.com/co-moglo-pojsc-zle-cz-ii/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Syfon wannowy jako dowód na postęp</title>
		<link>https://jureknawrocki.com/syfon-wannowy-jako-dowod-na-postep/</link>
					<comments>https://jureknawrocki.com/syfon-wannowy-jako-dowod-na-postep/#respond</comments>
		
		<dc:creator><![CDATA[Jerzy Nawrocki]]></dc:creator>
		<pubDate>Fri, 02 Aug 2024 17:41:41 +0000</pubDate>
				<category><![CDATA[Instalacje budowalne]]></category>
		<category><![CDATA[Z życia rzeczoznawcy]]></category>
		<category><![CDATA[Instalacje budowlane]]></category>
		<category><![CDATA[PVC]]></category>
		<guid isPermaLink="false">https://jureknawrocki.com/?p=2547</guid>

					<description><![CDATA[<p>Remontuję mieszkanie z lat 60-tych w ładnej dzielnicy Warszawy. Dziś przyszedł czas na instalacje w łazience. Chciałem zostawić piękną żeliwną wannę, której nie ma już w handlu. Aby to zrobić musiałem wyrwać żeliwny syfon, który ważył chyba z 7 kg. Syfon z PCV, który zamontowałem ważył 30 dkg. Tak wygląda rura kanalizacyjna żeliwna DN 50 [&#8230;]</p>
<p>The post <a href="https://jureknawrocki.com/syfon-wannowy-jako-dowod-na-postep/">Syfon wannowy jako dowód na postęp</a> appeared first on <a href="https://jureknawrocki.com">Jerzy Nawrocki</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<p>Remontuję mieszkanie z lat 60-tych w ładnej dzielnicy Warszawy. Dziś przyszedł czas na instalacje w łazience.  Chciałem zostawić piękną żeliwną wannę, której nie ma już w handlu. Aby to zrobić musiałem wyrwać żeliwny syfon, który ważył chyba z 7 kg. Syfon z PCV, który zamontowałem ważył 30 dkg. </p>



<figure class="wp-block-image size-large is-resized"><img loading="lazy" decoding="async" width="1024" height="461" src="https://jureknawrocki.com/wp-content/uploads/Wanna-1-1024x461.webp" alt="" class="wp-image-2550" style="width:823px;height:auto" srcset="https://jureknawrocki.com/wp-content/uploads/Wanna-1-980x441.webp 980w, https://jureknawrocki.com/wp-content/uploads/Wanna-1-480x216.webp 480w" sizes="(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1024px, 100vw" /></figure>



<figure class="wp-block-image size-large"><img loading="lazy" decoding="async" width="1024" height="611" src="https://jureknawrocki.com/wp-content/uploads/Wanna-2-1024x611.webp" alt="" class="wp-image-2549" srcset="https://jureknawrocki.com/wp-content/uploads/Wanna-2-980x585.webp 980w, https://jureknawrocki.com/wp-content/uploads/Wanna-2-480x287.webp 480w" sizes="(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1024px, 100vw" /></figure>



<p></p>



<figure class="wp-block-image size-full is-resized"><img loading="lazy" decoding="async" width="432" height="411" src="https://jureknawrocki.com/wp-content/uploads/Wanna-3.webp" alt="" class="wp-image-2548" style="width:823px;height:auto" srcset="https://jureknawrocki.com/wp-content/uploads/Wanna-3.webp 432w, https://jureknawrocki.com/wp-content/uploads/Wanna-3-300x285.webp 300w, https://jureknawrocki.com/wp-content/uploads/Wanna-3-13x12.webp 13w" sizes="(max-width: 432px) 100vw, 432px" /></figure>



<p>Tak wygląda rura kanalizacyjna żeliwna DN 50 po 60 latach użytkowania w bloku. Przelot rury kompletnie zamknięty przez rdzę i jakieś odpady.</p>



<figure class="wp-block-image size-large"><img loading="lazy" decoding="async" width="1024" height="461" src="https://jureknawrocki.com/wp-content/uploads/Wanna-4-1024x461.webp" alt="" class="wp-image-2553" srcset="https://jureknawrocki.com/wp-content/uploads/Wanna-4-980x441.webp 980w, https://jureknawrocki.com/wp-content/uploads/Wanna-4-480x216.webp 480w" sizes="(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1024px, 100vw" /></figure>



<figure class="wp-block-image size-large"><img loading="lazy" decoding="async" width="1024" height="461" src="https://jureknawrocki.com/wp-content/uploads/Wanna-5-1024x461.webp" alt="" class="wp-image-2554" srcset="https://jureknawrocki.com/wp-content/uploads/Wanna-5-980x441.webp 980w, https://jureknawrocki.com/wp-content/uploads/Wanna-5-480x216.webp 480w" sizes="(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1024px, 100vw" /></figure>
<p>The post <a href="https://jureknawrocki.com/syfon-wannowy-jako-dowod-na-postep/">Syfon wannowy jako dowód na postęp</a> appeared first on <a href="https://jureknawrocki.com">Jerzy Nawrocki</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://jureknawrocki.com/syfon-wannowy-jako-dowod-na-postep/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Obliczenia rurociągów z PVC cz. III</title>
		<link>https://jureknawrocki.com/obliczenia-rurociagow-z-pvc-cz-iii/</link>
					<comments>https://jureknawrocki.com/obliczenia-rurociagow-z-pvc-cz-iii/#respond</comments>
		
		<dc:creator><![CDATA[Jerzy Nawrocki]]></dc:creator>
		<pubDate>Thu, 01 Aug 2024 08:22:12 +0000</pubDate>
				<category><![CDATA[Obliczenia wytrzymałościowe rur i aparatów]]></category>
		<category><![CDATA[Z życia rzeczoznawcy]]></category>
		<category><![CDATA[Naprężenia]]></category>
		<category><![CDATA[PVC]]></category>
		<guid isPermaLink="false">https://jureknawrocki.com/?p=2535</guid>

					<description><![CDATA[<p>Przykład układu pompowni ze zbiornikiem medium. Typowe rozwiązanie z podwójnym układem pompowym. Poniżej pokazuję kilka elementów instalacji z PVC.</p>
<p>The post <a href="https://jureknawrocki.com/obliczenia-rurociagow-z-pvc-cz-iii/">Obliczenia rurociągów z PVC cz. III</a> appeared first on <a href="https://jureknawrocki.com">Jerzy Nawrocki</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<p>Przykład układu pompowni ze zbiornikiem medium. Typowe rozwiązanie z podwójnym układem pompowym. </p>



<figure class="wp-block-image aligncenter size-full is-resized"><img loading="lazy" decoding="async" width="707" height="763" src="https://jureknawrocki.com/wp-content/uploads/PVC-III-1.webp" alt="" class="wp-image-2537" style="width:557px;height:auto" srcset="https://jureknawrocki.com/wp-content/uploads/PVC-III-1.webp 707w, https://jureknawrocki.com/wp-content/uploads/PVC-III-1-480x518.webp 480w" sizes="(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 707px, 100vw" /></figure>



<figure class="wp-block-image aligncenter size-full is-resized"><img loading="lazy" decoding="async" width="719" height="650" src="https://jureknawrocki.com/wp-content/uploads/PVC-III-8.webp" alt="" class="wp-image-2539" style="width:583px;height:auto" srcset="https://jureknawrocki.com/wp-content/uploads/PVC-III-8.webp 719w, https://jureknawrocki.com/wp-content/uploads/PVC-III-8-480x434.webp 480w" sizes="(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 719px, 100vw" /></figure>



<figure class="wp-block-image aligncenter size-full is-resized"><img loading="lazy" decoding="async" width="793" height="576" src="https://jureknawrocki.com/wp-content/uploads/PVC-III-9-1.webp" alt="" class="wp-image-2540" style="width:537px;height:auto" srcset="https://jureknawrocki.com/wp-content/uploads/PVC-III-9-1.webp 793w, https://jureknawrocki.com/wp-content/uploads/PVC-III-9-1-480x349.webp 480w" sizes="(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 793px, 100vw" /></figure>



<figure class="wp-block-image aligncenter size-full is-resized"><img loading="lazy" decoding="async" width="802" height="763" src="https://jureknawrocki.com/wp-content/uploads/PVC-III-2.webp" alt="" class="wp-image-2538" style="width:558px;height:auto" srcset="https://jureknawrocki.com/wp-content/uploads/PVC-III-2.webp 802w, https://jureknawrocki.com/wp-content/uploads/PVC-III-2-480x457.webp 480w" sizes="(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 802px, 100vw" /></figure>



<p>Poniżej pokazuję kilka elementów instalacji z PVC. </p>



<figure class="wp-block-image aligncenter size-full is-resized"><img loading="lazy" decoding="async" width="579" height="634" src="https://jureknawrocki.com/wp-content/uploads/PVC-III-3.webp" alt="" class="wp-image-2541" style="width:514px;height:auto" srcset="https://jureknawrocki.com/wp-content/uploads/PVC-III-3.webp 579w, https://jureknawrocki.com/wp-content/uploads/PVC-III-3-480x526.webp 480w" sizes="(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 579px, 100vw" /></figure>



<figure class="wp-block-image aligncenter size-full is-resized"><img loading="lazy" decoding="async" width="564" height="785" src="https://jureknawrocki.com/wp-content/uploads/PVC-III-4.webp" alt="" class="wp-image-2542" style="width:558px;height:auto" srcset="https://jureknawrocki.com/wp-content/uploads/PVC-III-4.webp 564w, https://jureknawrocki.com/wp-content/uploads/PVC-III-4-480x668.webp 480w" sizes="(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 564px, 100vw" /></figure>



<figure class="wp-block-image aligncenter size-full is-resized"><img loading="lazy" decoding="async" width="564" height="755" src="https://jureknawrocki.com/wp-content/uploads/PVC-III-5.webp" alt="" class="wp-image-2543" style="width:564px;height:auto" srcset="https://jureknawrocki.com/wp-content/uploads/PVC-III-5.webp 564w, https://jureknawrocki.com/wp-content/uploads/PVC-III-5-480x643.webp 480w" sizes="(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 564px, 100vw" /></figure>



<figure class="wp-block-image aligncenter size-full"><img loading="lazy" decoding="async" width="549" height="726" src="https://jureknawrocki.com/wp-content/uploads/PVC-III-6.webp" alt="" class="wp-image-2544" srcset="https://jureknawrocki.com/wp-content/uploads/PVC-III-6.webp 549w, https://jureknawrocki.com/wp-content/uploads/PVC-III-6-480x635.webp 480w" sizes="(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 549px, 100vw" /></figure>



<figure class="wp-block-image aligncenter size-large"><img loading="lazy" decoding="async" width="1024" height="622" src="https://jureknawrocki.com/wp-content/uploads/PVC-III-7-1024x622.webp" alt="" class="wp-image-2545" srcset="https://jureknawrocki.com/wp-content/uploads/PVC-III-7-1024x622.webp 1024w, https://jureknawrocki.com/wp-content/uploads/PVC-III-7-980x595.webp 980w, https://jureknawrocki.com/wp-content/uploads/PVC-III-7-480x292.webp 480w" sizes="(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1024px, 100vw" /></figure>
<p>The post <a href="https://jureknawrocki.com/obliczenia-rurociagow-z-pvc-cz-iii/">Obliczenia rurociągów z PVC cz. III</a> appeared first on <a href="https://jureknawrocki.com">Jerzy Nawrocki</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://jureknawrocki.com/obliczenia-rurociagow-z-pvc-cz-iii/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Obliczenia rurociągów z PVC cz. II</title>
		<link>https://jureknawrocki.com/obliczenia-rurociagow-z-pvc-cz-ii/</link>
					<comments>https://jureknawrocki.com/obliczenia-rurociagow-z-pvc-cz-ii/#respond</comments>
		
		<dc:creator><![CDATA[Jerzy Nawrocki]]></dc:creator>
		<pubDate>Tue, 30 Jul 2024 06:18:46 +0000</pubDate>
				<category><![CDATA[Obliczenia wytrzymałościowe rur i aparatów]]></category>
		<category><![CDATA[Z życia rzeczoznawcy]]></category>
		<category><![CDATA[AutoPipe]]></category>
		<category><![CDATA[Naprężenia]]></category>
		<category><![CDATA[PVC]]></category>
		<guid isPermaLink="false">https://jureknawrocki.com/?p=2525</guid>

					<description><![CDATA[<p>Na poniższym przykładzie pokazano jak niewiele trzeba aby obciążenia na króćcach zostały przekroczone. Temperatura montażu to 15C, a obliczeniowa 30C. Kod B31.3. Przy tak małej różnicy temperatur, która spowodowała wydłużenie termiczne zaledwie o 1mm, jeżeli króćce dwóch zbiorników zostały połączone prostą rurką DN 100 na sztywno bez żadnej samokompensacji, to nastąpią przekroczenia siły i momentów [&#8230;]</p>
<p>The post <a href="https://jureknawrocki.com/obliczenia-rurociagow-z-pvc-cz-ii/">Obliczenia rurociągów z PVC cz. II</a> appeared first on <a href="https://jureknawrocki.com">Jerzy Nawrocki</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<p>Na poniższym przykładzie pokazano jak niewiele trzeba aby obciążenia na króćcach zostały przekroczone. Temperatura montażu to 15C, a obliczeniowa 30C. Kod B31.3. Przy tak małej różnicy temperatur, która spowodowała wydłużenie termiczne zaledwie o 1mm, jeżeli króćce dwóch zbiorników zostały połączone prostą rurką DN 100 na sztywno bez żadnej samokompensacji, to nastąpią przekroczenia siły i momentów na tychże króćcach o około 150 %. </p>



<p>Z tego przypadku wynika zalecenie aby nigdy nie łączyć się do króćców prostym odcinkiem, który z jednej strony jest opiera się o drugi króciec lub o punkt stały. Na poniższym szkicu widać takie właśnie połączenie pomiędzy króćcami zaznaczonymi jako dwa żółte kołnierze.      </p>



<figure class="wp-block-image aligncenter size-large is-resized"><img loading="lazy" decoding="async" width="1024" height="597" src="https://jureknawrocki.com/wp-content/uploads/PVC-II-1-1024x597.jpg" alt="" class="wp-image-2526" style="width:739px;height:auto" srcset="https://jureknawrocki.com/wp-content/uploads/PVC-II-1-1024x597.jpg 1024w, https://jureknawrocki.com/wp-content/uploads/PVC-II-1-980x572.jpg 980w, https://jureknawrocki.com/wp-content/uploads/PVC-II-1-480x280.jpg 480w" sizes="(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1024px, 100vw" /></figure>



<p>Tutaj jest model fragmentu instalacji. Chodzi o króćce u spodu zbiorników na końcu ich części stożkowych. </p>



<figure class="wp-block-image aligncenter size-full is-resized"><img loading="lazy" decoding="async" width="599" height="481" src="https://jureknawrocki.com/wp-content/uploads/PVC-II-2.jpg" alt="" class="wp-image-2527" style="width:621px;height:auto" srcset="https://jureknawrocki.com/wp-content/uploads/PVC-II-2.jpg 599w, https://jureknawrocki.com/wp-content/uploads/PVC-II-2-480x385.jpg 480w" sizes="(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 599px, 100vw" /></figure>



<p>Poniżej pokazano wyniki naprężeń, które są jak najbardziej prawidłowe. </p>



<figure class="wp-block-image size-large"><img loading="lazy" decoding="async" width="1024" height="461" src="https://jureknawrocki.com/wp-content/uploads/PVC-II-3-1024x461.jpg" alt="" class="wp-image-2528" srcset="https://jureknawrocki.com/wp-content/uploads/PVC-II-3-980x441.jpg 980w, https://jureknawrocki.com/wp-content/uploads/PVC-II-3-480x216.jpg 480w" sizes="(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1024px, 100vw" /></figure>



<p>Poniżej pokazano wyniki odkształceń, które też nie budzą jakiś specjalnych wątpliwości.  </p>



<figure class="wp-block-image aligncenter size-large is-resized"><img loading="lazy" decoding="async" width="1024" height="513" src="https://jureknawrocki.com/wp-content/uploads/PVC-II-4-1024x513.jpg" alt="" class="wp-image-2529" style="width:823px;height:auto" srcset="https://jureknawrocki.com/wp-content/uploads/PVC-II-4-980x491.jpg 980w, https://jureknawrocki.com/wp-content/uploads/PVC-II-4-480x240.jpg 480w" sizes="(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1024px, 100vw" /></figure>



<p>Na koniec wyniki przekroczeń na króćcach. </p>



<figure class="wp-block-image aligncenter size-full"><img loading="lazy" decoding="async" width="876" height="452" src="https://jureknawrocki.com/wp-content/uploads/PVC-II-5.jpg" alt="" class="wp-image-2530" srcset="https://jureknawrocki.com/wp-content/uploads/PVC-II-5.jpg 876w, https://jureknawrocki.com/wp-content/uploads/PVC-II-5-480x248.jpg 480w" sizes="(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 876px, 100vw" /></figure>
<p>The post <a href="https://jureknawrocki.com/obliczenia-rurociagow-z-pvc-cz-ii/">Obliczenia rurociągów z PVC cz. II</a> appeared first on <a href="https://jureknawrocki.com">Jerzy Nawrocki</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://jureknawrocki.com/obliczenia-rurociagow-z-pvc-cz-ii/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Obliczenia rurociągów PVC</title>
		<link>https://jureknawrocki.com/obliczenia-rurociagow-pvc/</link>
					<comments>https://jureknawrocki.com/obliczenia-rurociagow-pvc/#respond</comments>
		
		<dc:creator><![CDATA[Jerzy Nawrocki]]></dc:creator>
		<pubDate>Wed, 05 Jun 2024 10:27:12 +0000</pubDate>
				<category><![CDATA[Obliczenia wytrzymałościowe rur i aparatów]]></category>
		<category><![CDATA[Z życia rzeczoznawcy]]></category>
		<category><![CDATA[FRP]]></category>
		<category><![CDATA[Naprężenia]]></category>
		<category><![CDATA[PVC]]></category>
		<guid isPermaLink="false">https://jureknawrocki.com/?p=2400</guid>

					<description><![CDATA[<p>Obliczenia wytrzymałościowe rur plastikowych mają jedną ważną cechę: bardzo niskie naprężenia dopuszczalne i bardzo wysokie wydłużenie. Jest to połączenie dwóch cech w wyjątkowo niekorzystny sposób. Poniżej instalacja z PVC podłączona do zbiornika z FRP. Króćce tego zbiornika mają bardzo małą wytrzymałość więc trzeba dbać o samokompensację.</p>
<p>The post <a href="https://jureknawrocki.com/obliczenia-rurociagow-pvc/">Obliczenia rurociągów PVC</a> appeared first on <a href="https://jureknawrocki.com">Jerzy Nawrocki</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<p>Obliczenia wytrzymałościowe rur plastikowych mają jedną ważną cechę: bardzo niskie naprężenia dopuszczalne i bardzo wysokie wydłużenie. Jest to połączenie dwóch cech w wyjątkowo niekorzystny sposób. Poniżej instalacja z PVC podłączona do zbiornika z FRP. Króćce tego zbiornika mają bardzo małą wytrzymałość więc trzeba dbać o samokompensację.  </p>



<figure class="wp-block-image size-large"><img loading="lazy" decoding="async" width="1024" height="582" src="https://jureknawrocki.com/wp-content/uploads/FRP2-1024x582.webp" alt="" class="wp-image-2402" srcset="https://jureknawrocki.com/wp-content/uploads/FRP2-1024x582.webp 1024w, https://jureknawrocki.com/wp-content/uploads/FRP2-980x557.webp 980w, https://jureknawrocki.com/wp-content/uploads/FRP2-480x273.webp 480w" sizes="(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1024px, 100vw" /></figure>



<figure class="wp-block-image size-full"><img loading="lazy" decoding="async" width="965" height="635" src="https://jureknawrocki.com/wp-content/uploads/FRP1.webp" alt="" class="wp-image-2401" srcset="https://jureknawrocki.com/wp-content/uploads/FRP1.webp 965w, https://jureknawrocki.com/wp-content/uploads/FRP1-480x316.webp 480w" sizes="(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 965px, 100vw" /></figure>
<p>The post <a href="https://jureknawrocki.com/obliczenia-rurociagow-pvc/">Obliczenia rurociągów PVC</a> appeared first on <a href="https://jureknawrocki.com">Jerzy Nawrocki</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://jureknawrocki.com/obliczenia-rurociagow-pvc/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Very detail engineering czyli pipe stress i rura w rurze</title>
		<link>https://jureknawrocki.com/very-detail-engineering-czyli-pipe-stress-i-rura-w-rurze/</link>
		
		<dc:creator><![CDATA[Jerzy Nawrocki]]></dc:creator>
		<pubDate>Tue, 04 Apr 2023 07:56:42 +0000</pubDate>
				<category><![CDATA[Obliczenia wytrzymałościowe rur i aparatów]]></category>
		<category><![CDATA[Z życia rzeczoznawcy]]></category>
		<category><![CDATA[PVC]]></category>
		<guid isPermaLink="false">http://www.jureknawrocki.com/?p=912</guid>

					<description><![CDATA[<p>Bardzo wymagający system dla pipe stresowca. System świetnie nadaje się do niezbyt gorących ale bardzo niebezpiecznych mediów. System z podwójną obudową to system z podwójną ścianą, w którym jedna rura znajduje się wewnątrz drugiej rury. Rura wewnętrzna nazywana jest rurą „pierwotną” lub „nośną”, podczas gdy rura zewnętrzna nazywana jest rurą „wtórną” lub „osłaniającą”. Aby zapewnić [&#8230;]</p>
<p>The post <a href="https://jureknawrocki.com/very-detail-engineering-czyli-pipe-stress-i-rura-w-rurze/">Very detail engineering czyli pipe stress i rura w rurze</a> appeared first on <a href="https://jureknawrocki.com">Jerzy Nawrocki</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Bardzo wymagający system dla pipe stresowca.</p>
<p>System świetnie nadaje się do niezbyt gorących ale bardzo niebezpiecznych mediów. System z podwójną obudową to system z podwójną ścianą, w którym jedna rura znajduje się wewnątrz drugiej rury. Rura wewnętrzna nazywana jest rurą „pierwotną” lub „nośną”, podczas gdy rura zewnętrzna nazywana jest rurą „wtórną” lub „osłaniającą”. Aby zapewnić wsparcie dla rury nośnej i aby utrzymać go w środku rury zabezpieczającej, stosuje się centralizatory (przekładki). Podwójny system zabezpieczający służy do zapobiegania wyciekom niebezpiecznych płynów – tzw dodatkowe przewody rurowe zawierałyby wyciekający płyn, gdyby wystąpiła awaria przewodu pierwotnego.</p>
<p style="text-align: center;"><img loading="lazy" decoding="async" class="alignnone size-full wp-image-1633" src="https://jn.proklik.pl/wp-content/uploads/Plastiki-DC-1.webp" alt="" width="291" height="180" /></p>
<p>Liczenie takich systemów zwłaszcza na pustynnych terenach sejsmicznych jest już wyższą szkołą jazdy w dziedzinie pipe stresu.  Poniżej estakada 134 m długości z systemem 8/4 cale.</p>
<p><img loading="lazy" decoding="async" class="size-full wp-image-1643" src="https://jn.proklik.pl/wp-content/uploads/Plastiki-DC-2.webp" alt="Jerzy Nawrocki - Plastiki DC-2" width="632" height="394" srcset="https://jn.proklik.pl/wp-content/uploads/Plastiki-DC-2.webp 632w, https://jn.proklik.pl/wp-content/uploads/Plastiki-DC-2-480x299.webp 480w" sizes="(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 632px, 100vw" /></p>
<p style="text-align: center;">Widać poniżej wymodelowany system rura-w rurze:</p>
<p><img loading="lazy" decoding="async" class="size-full wp-image-1642" src="https://jn.proklik.pl/wp-content/uploads/Plastiki-DC-3.webp" alt="Jerzy Nawrocki - Plastiki DC-3" width="481" height="308" srcset="https://jureknawrocki.com/wp-content/uploads/Plastiki-DC-3.webp 481w, https://jureknawrocki.com/wp-content/uploads/Plastiki-DC-3-300x192.webp 300w" sizes="(max-width: 481px) 100vw, 481px" /></p>
<p style="text-align: center;">
<p>The post <a href="https://jureknawrocki.com/very-detail-engineering-czyli-pipe-stress-i-rura-w-rurze/">Very detail engineering czyli pipe stress i rura w rurze</a> appeared first on <a href="https://jureknawrocki.com">Jerzy Nawrocki</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
